TapBus Line

TapBus Modbus-Wireless I/O Blocks

Create Connected Industrial Systems or Retrofit for the IIoT with Programmable Power & Data Acquisition Modules

Designers of industrial systems turn to TapBus for the wireless building blocks that they need to create connected systems or retrofit infrastructure for the IIoT. 

TapBus programmable power supply, metering and IO modules include pre-implemented communication interfaces, automatic addressing, encryption and configurable access control. Using these requires no coding. With its embedded Java Virtual Machine and a few lines of code, designers can retrieve sensor data and drive other devices. Designers can even create complex logic for synchronizing components. Retrieved data can be transformed and transmitted to supervisory cloud platforms or servicing apps.

TapBus Modbus (RTU or TCP) communication over RS485 or Ethernet offers automatic addressing and chaining via DIN rail or ribbon cable. TapBus native wireless interfaces (NFC, Bluetooth, Wi-Fi) simplify connection to mobile devices for system commissioning, and maintenance. LPWAN add-ons for LoRa and LTE-M and just a few lines of code allow designers to send data to any cloud supervisory platform. With our supporting tool ecosystem, they can rapidly create customized servicing apps and supervisory dashboards that meet users' specific requirements. 

 

Request Prices and Samples from contact@iotize.com

 

TapBus Master Power Module

  • Modbus TCP, RTU protocol support
  • RS485, Ethernet interfaces
  • DIN-Rail Bus or Ribbon cable
  • Up to 32 slave devices
  • Native NFC, Bluetooth, Wi-Fi
  • LoRa, LTE-M add-ons
  • 220 V AC / 24-36 V DC power input
  • 5 or 12 V power output
  • Backup battery management
TapBus Master Power Module

TapBus Wattmeter Slave Module

  • Single phase 100 - 250 V
  • 6 inputs for 0.333 V current transformers (10, 50, or 100 A)
  • Measures Voltage, Current, Power, Energy, Phase
  • Modbus RTU protocol support
  • RS485  interface
  • Native NFC
  • 3-color LED per channel
  • Opto-isolation to 1 kV
  • -25º to 70º C, 55% humidity
TapBus Wattmeter Slave Module

TapBus Analog IO Slave Module

  • 24-bit ADC
  • 16 configurable inputs
  • 4-20 mA, 0 - 10 V or 0 - 2 V
  • Pt100 / Pt1000 (2 or 3-wire)
  • Modbus RTU protocol support
  • RS485  interface
  • Native NFC
  • 3-color LED per channel
  • Opto-isolation to 1.5 kV
  • Precision 0.01% of full scale at 25º C
  • -25º to 70º C, 55% humidity
TapBus Analog IO Slave Module

TapBus Digital IO Slave Module

  • Sampling at 1 kHz
  • 12 configurable inputs: Digital, Counter, Timer, Frequency Meter
  • 4 configurable outputs: Digital, Pulse, PWM8
  • Electric switches (to 60 V)
  • Modbus RTU protocol support
  • RS485  interface
  • Native NFC
  • 3-color LED per channel
  • Opto-isolation to 1.5 kV
  • -25º to 70º C, 55% humidity
TapBus Digital IO Slave Module